Have your system checked each year by a certified refrigeration technician. He should:
Unit will not reach temperature | Call your installation contractor to Determine proper refrigerant charge. Dirty condenser? |
Unit has shut off | Call BSC tech services or field Service; could be bad Compressor, fans, controller or Pump |
Alarm conditions on the electronic controller email us at service@bacchuswinecellars.com
Alarm Signaling
|
||
---|---|---|
Message | Cause | Outputs |
“P1” | Thermostat probe failure | Compressor and heating outputs off (on dehumidification system only) |
“P3” | Humidity probe failure | Humidity regulation off |
“HA” | High temp alarm | Outputs unchanged |
“LA” | Low temperature alarm | Outputs unchanged |
“HHA” | High humidity alarm | Outputs unchanged |
“HLA” | Low humidity alarm | Outputs unchanged |
In the instance of any of these alarms, call Bacchus Technical Services, or your local service contractor
BCS1000 Cond.Unit | BCS1000 Evap | BCS1500 Cond Unit | BCS1500 Evaporator | BCS2000 Cond Unit | BCS3000 Cond Unit | |
---|---|---|---|---|---|---|
Dimensions | 17″D x 13.3″W x 11.8″H | 18″D x 29.25″W x 6.5″H | 19″D x 16.2″W x 14″H | 18″D x 29.25″W x 6.5″H | 19″D x 21′W x 16.5″H | 25″ D x 20″W x 16″H |
Weight | 51 lbs. | 49 lbs. | 62 lbs. | 51 lbs. | 81 lbs. | 135 lbs. |
Refrigerant connection | 3/8″ suc. 1/4″ dis. | 3/8″sw | 3/8″ suc. 1/4″ dis. | 3/8″ sw x 1/2″ sw | 3/8″suc. 5/16″ dis. | 1/2″suc. 3/8″ dis. |
Water Supply connection | – | 1/4″ compression | – | 1/4″ compression | – | – |
Condensate connection | – | 3/8″ mpt | – | 3/8″ mpt | – | – |
Compressor HP / voltage | 1/2 hp 115v | – | .65 hp115v | – | 1 hp 115v | 1 1/2 hp 208/230-1v |
Electrical | – | – | – | – | – | – |
Compressor RLA | 10A | – | 11A | – | 8A | 12.1A |
Compressor LRA | 53A | – | 51A | – | 43A | 49A |
Cond. Unit MFS | 20A | – | 30A | – | 15A | 17.6A |
Cond. Unit MCA | 13.4A | – | 13.4A | – | 11.3A | 12.1A |
BTU capacity 40F Suc., 110 Amb. | 4857 | – | 6250 | – | 10200 (100f amb) | 12,185 |